11 research outputs found

    Quantification of functional weakness and abnormal synergy patterns in the lower limb of individuals with chronic stroke

    Get PDF
    BACKGROUND: The presence of abnormal muscle activation patterns is a well documented factor limiting the motor rehabilitation of patients following stroke. These abnormal muscle activation patterns, or synergies, have previously been quantified in the upper limbs. Presented here are the lower limb joint torque patterns measured in a standing position of sixteen chronic hemiparetic stroke subjects and sixteen age matched controls used to examine differences in strength and coordination between the two groups. METHODS: With the trunk stabilized, stroke subjects stood on their unaffected leg while their affected foot was attached to a 6-degree of freedom load cell (JR3, Woodland CA) which recorded forces and torques. The subjects were asked to generate a maximum torque about a given joint (hip abduction/adduction; hip, knee, and ankle flexion/extension) and provided feedback of the torque they generated for that primary joint axis. In parallel, EMG data from eight muscle groups were recorded, and secondary torques generated about the adjacent joints were calculated. Differences in mean primary torque, secondary torque, and EMG data were compared using a single factor ANOVA. RESULTS: The stroke group was significantly weaker in six of the eight directions tested. Analysis of the secondary torques showed that the control and stroke subjects used similar strategies to generate maximum torques during seven of the eight joint movements tested. The only time a different strategy was used was during maximal hip abduction exertions where stroke subjects tended to flex instead of extend their hip, which was consistent with the classically defined "flexion synergy." The EMG data of the stroke group was different than the control group in that there was a strong presence of co-contraction of antagonistic muscle groups, especially during ankle flexion and ankle and knee extension. CONCLUSION: The results of this study indicate that in a standing position stroke subjects are significantly weaker in their affected leg when compared to age-matched controls, yet showed little evidence of the classic lower-limb abnormal synergy patterns previously reported. The findings here suggest that the primary contributor to isometric lower limb motor deficits in chronic stroke subjects is weakness

    Abnormal joint torque patterns exhibited by chronic stroke subjects while walking with a prescribed physiological gait pattern

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It is well documented that individuals with chronic stroke often exhibit considerable gait impairments that significantly impact their quality of life. While stroke subjects often walk asymmetrically, we sought to investigate whether prescribing near normal physiological gait patterns with the use of the Lokomat robotic gait-orthosis could help ameliorate asymmetries in gait, specifically, promote similar ankle, knee, and hip joint torques in both lower extremities. We hypothesized that hemiparetic stroke subjects would demonstrate significant differences in total joint torques in both the frontal and sagittal planes compared to non-disabled subjects despite walking under normal gait kinematic trajectories.</p> <p>Methods</p> <p>A motion analysis system was used to track the kinematic patterns of the pelvis and legs of 10 chronic hemiparetic stroke subjects and 5 age matched controls as they walked in the Lokomat. The subject's legs were attached to the Lokomat using instrumented shank and thigh cuffs while instrumented footlifters were applied to the impaired foot of stroke subjects to aid with foot clearance during swing. With minimal body-weight support, subjects walked at 2.5 km/hr on an instrumented treadmill capable of measuring ground reaction forces. Through a custom inverse dynamics model, the ankle, knee, and hip joint torques were calculated in both the frontal and sagittal planes. A single factor ANOVA was used to investigate differences in joint torques between control, unimpaired, and impaired legs at various points in the gait cycle.</p> <p>Results</p> <p>While the kinematic patterns of the stroke subjects were quite similar to those of the control subjects, the kinetic patterns were very different. During stance phase, the unimpaired limb of stroke subjects produced greater hip extension and knee flexion torques than the control group. At pre-swing, stroke subjects inappropriately extended their impaired knee, while during swing they tended to abduct their impaired leg, both being typical abnormal torque synergy patterns common to stroke gait.</p> <p>Conclusion</p> <p>Despite the Lokomat guiding stroke subjects through physiologically symmetric kinematic gait patterns, abnormal asymmetric joint torque patterns are still generated. These differences from the control group are characteristic of the hip hike and circumduction strategy employed by stroke subjects.</p

    Role of Robotics in Neurorehabilitation

    No full text

    Kinematic trajectories while walking within the Lokomat robotic gait-orthosis,” Clinical Biomechanics

    No full text
    Abstract Background One of the most popular robot assisted rehabilitation devices used is the Lokomat. Unfortunately, not much is known about the behaviors exhibited by subjects in this device. The goal of this study was to evaluate the kinematic patterns of individuals walking inside the Lokomat compared to those demonstrated on a treadmill. Methods Six healthy subjects walked on a treadmill and inside the Lokomat while the motions of the subject and Lokomat were tracked. Joint angles and linear motion were determined for Lokomat and treadmill walking. We also evaluated the variability of the patterns, and the repeatability of measuring techniques. Findings The overall kinematics in the Lokomat are similar to those on a treadmill, however there was significantly more hip and ankle extension, and greater hip and ankle range of motion in the Lokomat (P &lt; 0.05). Additionally, the linear movement of joints was reduced in the Lokomat. Subjects tested on repeated sessions presented consistent kinematics, demonstrating the ability to consistently setup and test subjects. Interpretation The reduced degrees of freedom in the Lokomat are believed to be the reason for the specific kinematic differences. We found that despite being firmly attached to the device there was still subject movement relative to the Lokomat. This led to variability in the patterns, where subjects altered their gait pattern from step to step. These results are clinically important as a variable step pattern has been shown to be a more effective gait training strategy than one which forces the same kinematic pattern in successive steps

    Biomechanics of overground vs. treadmill walking in healthy individuals

    No full text

    Fiber optic micro sensor for the measurement of tendon forces

    Get PDF
    <p>Abstract</p> <p>A fiber optic sensor developed for the measurement of tendon forces was designed, numerically modeled, fabricated, and experimentally evaluated. The sensor incorporated fiber Bragg gratings and micro-fabricated stainless steel housings. A fiber Bragg grating is an optical device that is spectrally sensitive to axial strain. Stainless steel housings were designed to convert radial forces applied to the housing into axial forces that could be sensed by the fiber Bragg grating. The metal housings were fabricated by several methods including laser micromachining, swaging, and hydroforming. Designs are presented that allow for simultaneous temperature and force measurements as well as for simultaneous resolution of multi-axis forces.</p> <p>The sensor was experimentally evaluated by hydrostatic loading and <it>in vitro</it> testing. A commercial hydraulic burst tester was used to provide uniform pressures on the sensor in order to establish the linearity, repeatability, and accuracy characteristics of the sensor. The <it>in vitro</it> experiments were performed in excised tendon and in a dynamic gait simulator to simulate biological conditions. In both experimental conditions, the sensor was found to be a sensitive and reliable method for acquiring minimally invasive measurements of soft tissue forces. Our results suggest that this sensor will prove useful in a variety of biomechanical measurements.</p

    ZeroG: overground gait and balance training system

    No full text
    A new overground body-weight support system called ZeroG has been developed that allows patients with severe gait impairments to practice gait and balance activities in a safe, controlled manner. The unloading system is capable of providing up to 300 lb of static support and 150 lb of dynamic (or constant force) support using a custom-series elastic actuator. The unloading system is mounted to a driven trolley, which rides along an overhead rail. We evaluated the performance of ZeroG's unloading system, as well as the trolley tracking system, using benchtop and human-subject testing. Average root-mean-square and peak errors in unloading were 2.2 and 7.2 percent, respectively, over the range of forces tested while trolley tracking errors were less than 3 degrees, indicating the system was able to maintain its position above the subject. We believe training with ZeroG will allow patients to practice activities that are critical to achieving functional independence at home and in the community
    corecore